Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Rev. bras. ortop ; 57(2): 327-333, Mar.-Apr. 2022. tab, graf
Article in English | LILACS | ID: biblio-1387990

ABSTRACT

Abstract Objective We aimed to study the "in vitro" pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping.


Resumo Objetivo Nosso objetivo foi estudar a resistência à extração "in vitro" do parafuso SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct (Parafuso DSG Guia Cirúrgico Dinâmico, SpineGuard Inc, Boulder, Colorado, USA), um parafuso projetado para ser inserido utilizando a técnica de inserção direta. Métodos Os parafusos DSG de 5,5 e 6,5 mm foram introduzidos em blocos de poliuretano com densidade de 10 PCF (0,16g/cm3). De acordo com o grupo experimental, os parafusos foram inseridos sem um orifício piloto, com um orifício piloto sem o macheamento, com macheamento e com macheamento linha a linha. Os testes de extração do parafuso foram realizados em uma máquina de teste universal, após a inserção do parafuso em blocos de poliuretano. Resultados Os parafusos inseridos diretamente nos blocos de poliuretano sem o orifício piloto e o macheamento mostraram uma resistência à extração estatisticamente maior. A inserção do parafuso sem o macheamento ou com o macho de menor diâmetro aumenta a resistência à extração do parafuso em comparação com o macheamento linha a linha. Conclusão O parafuso DSG apresentou a maior resistência à extração após a inserção sem o orifício piloto e o macheamento.


Subject(s)
Spinal Fusion , Biomechanical Phenomena/physiology , Bone Screws , Pedicle Screws
2.
Acta ortop. bras ; 30(spe2): e251579, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403060

ABSTRACT

ABSTRACT Introduction End-of-life cancer treatment is associated with substantial healthcare costs. Objective This study aimed to analyze the surgical treatment cost of spinal metastasis and epidural compression patients undergoing surgical treatment. Methods A retrospective cost analysis of 81 patients with spinal metastasis and epidural compression undergoing surgical treatment. Cost evaluation was defined in the following categories: medications, laboratory and imaging tests, nursery, recovery room, intensive care unit, surgical procedure, and consigned material. The cost of pain improvement, functional activity, and survival was also evaluated. Results The total cost of surgical treatment for 81 patients was $3,604,334.26, and the average value for each patient was $44,497.95. The highest costs were related to implants (41.1%), followed by hospitalization (27.3%) and surgical procedure (19.7%). Conclusion The cost of surgical treatment for spinal metastases is one of the most expensive bone complications in cancer patients. The cost of treatment related to outcomes showed differences according to the outcome analyzed. Hospital stay, tests, drugs, and intensive care play an important role in some of the costs related to the specific outcome. Level of Evidence II, Retrospective Study.


RESUMO Introdução O tratamento do câncer em fim de vida está associado a custos substanciais em saúde. Objetivo O objetivo do estudo foi analisar o custo do tratamento cirúrgico de pacientes com metástase espinhal e compressão peridural submetidos ao tratamento cirúrgico. Métodos Uma análise retrospectiva de custos de 81 pacientes com metástase espinhal e compressão peridural submetidos a tratamento cirúrgico. A avaliação de custos foi definida nas seguintes categorias: medicamentos, exames laboratoriais e de imagem, enfermaria, sala de recuperação, unidade de terapia intensiva, procedimento cirúrgico e material consignado. O custo relacionado à melhora da dor, atividade funcional e sobrevida também foi avaliado. Resultados O custo total do tratamento cirúrgico de 81 pacientes foi de R $ 3.604.334,26 e o valor médio de cada paciente foi de R $ 44.497,95. Os maiores gastos foram relacionados com implantes (41,1%), seguidos de internação (27,3%) e procedimento cirúrgico (19,7%). Conclusão O custo do tratamento cirúrgico para metástases espinhais é um dos mais caros entre as complicações ósseas em pacientes com câncer. O custo do tratamento relacionado aos desfechos apresentou diferença de acordo com o desfecho analisado e a permanência hospitalar, exames, medicamentos e terapia intensiva tem papel importante em alguns dos custos relacionados ao desfecho específico. Nível de Evidência II, Estudo retrospectivo.

3.
Coluna/Columna ; 19(3): 189-193, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1133571

ABSTRACT

ABSTRACT Objective To compare the use of a dynamic surgical guide (PediGuard®) and pilot hole preparation, with the use of a probe and the aid of fluoroscopy in osteoporotic or osteopenic patients undergoing pedicular fixation of the thoracic or lumbar spine. Methods One hundred and eight patients were randomized. A pilot hole was prepared with the dynamic surgical guide (PediGuard®), or with a probe with the aid of fluoroscopy. A total of 657 vertebral pedicles (120 thoracic and 180 lumbar) were included in the study. The parameters used for the comparison were: accuracy of the pedicular screw, number of fluoroscopic shots, and change in intraoperative trajectory of the perforation after detecting pedicle wall rupture. Results In the group with use of the dynamic surgical guide, malpositioning of the pedicle screws was observed in 8 (2.6%) patients and intraoperative change of perforation trajectory in 12 (4%) patients, and there were 52 fluoroscopic shots. In the group without use of the dynamic surgical guide (PediGuard®), misplacement of the pedicle screws was observed in 33 (11%) patients and intraoperative change of perforation trajectory in 47 (13.2%) patients, and there were 136 fluoroscopic shots. Conclusion The use of the dynamic surgical guide (PediGuard®) in patients with osteoporosis or osteopenia enabled more accurate placement of pedicular screws, with less change in the intraoperative course of the perforation and less intraoperative radiation. Level of Evidence II; Randomized clinical trial of lesser quality.


RESUMO Objetivo Comparar o uso de um guia cirúrgico dinâmico (PediGuard®) e o preparo de orifício piloto com uma sonda e o auxílio de fluoroscopia em pacientes com osteopenia ou osteoporose submetidos à fixação pedicular da coluna torácica ou lombar. Métodos Cento e oito pacientes foram randomizados. Um orifício piloto foi preparado com o guia cirúrgico dinâmico (PediGuard®) ou com uma sonda com auxílio de fluoroscopia. Foram incluídos no estudo 657 pedículos vertebrais (120 torácicos e 180 lombares). Os parâmetros usados para a comparação foram: acurácia da colocação do parafuso pedicular, número de disparos fluoroscópicos e mudança da trajetória intraoperatória da perfuração depois da detecção de ruptura da parede do pedículo. Resultados No grupo de pacientes em que se usou o guia cirúrgico dinâmico, observou-se mau posicionamento dos parafusos pediculares em oito (2,6%) pacientes e alteração da trajetória intraoperatória da perfuração em 12 (4%) pacientes, com 52 disparos fluoroscópicos. No grupo de pacientes em que o guia cirúrgico dinâmico (PediGuard®) não foi usado o mau posicionamento dos parafusos pediculares foi observado em 33 (11%) pacientes, a mudança intraoperatória da trajetória da perfuração foi vista em 47 (13,2%) pacientes, com 136 disparos fluoroscópicos. Conclusão O uso do guia cirúrgico dinâmico (PediGuard®) em pacientes com osteoporose ou osteopenia permitiu a colocação de parafusos pediculares com maior acurácia, com menor alteração da trajetória intraoperatória da perfuração e menor dose de radiação intraoperatória. Nível de Evidência II; Estudo clínico randomizado de menor qualidade.


RESUMEN Objetivo Comparar el uso de una guía quirúrgica dinámica (PediGuard®) y la preparación del orificio piloto con una sonda y la ayuda de fluoroscopia en pacientes con osteopenia u osteoporosis sometidos a fijación pedicular de la columna torácica o lumbar. Métodos Ciento ocho pacientes fueron asignados aleatoriamente. Se preparó un orificio piloto preparado con la guía quirúrgica dinámica (PediGuard®) o con una sonda con ayuda de fluoroscopia. Se incluyeron en el estudio 657 pedículos vertebrales (120 torácicos y 180 lumbares). Los parámetros utilizados para la comparación fueron: precisión de la colocación del tornillo pedicular, número de disparos del dispositivo de fluoroscopia y cambio en la trayectoria intraoperatoria de la perforación después de la detección de ruptura de la pared del pedículo. Resultados En el grupo de pacientes en el que se utilizó la guía quirúrgica dinámica, se observó mal posicionamiento de los tornillos pediculares en 8 (2,6%) pacientes y cambios de la trayectoria intraoperatoria de la perforación en 12 (4%) pacientes, con 52 disparos del aparato de fluoroscopia. En el grupo de pacientes en los que no se utilizó la guía quirúrgica dinámica (PediGuard®), se observó un mal posicionamiento de los tornillos pediculares en 33 (11%) pacientes, el cambio intraoperatorio de la trayectoria de perforación se observó en 47 (13,2%) pacientes, con 136 disparos fluoroscópicos. Conclusión El uso de la guía quirúrgica dinámica (PediGuard®) en pacientes con osteoporosis u osteopenia permitió la colocación de tornillos pediculares con mayor precisión, menos cambios en la trayectoria intraoperatoria de la perforación y dosis más baja de radiación intraoperatoria. Nivel de Evidencia II; Ensayo clínico aleatorizado de menor calidad.


Subject(s)
Humans , Orifice Valves , Bone Diseases, Metabolic , Bone Screws , Fluoroscopy
4.
Acta ortop. bras ; 26(5): 335-337, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-973571

ABSTRACT

ABSTRACT Objective: To assess the intra- and inter-observer reliability of a Brazilian Portuguese translated and cross-culturally adapted version of the mJOA questionnaire. Methods: The reliability of the Brazilian Portuguese version of the mJOA scale was assessed through the evaluation of a sample of patients with cervical myelopathy by two independent experienced spine surgeon examiners. Inter-observer reliability was defined by the Intraclass Correlation Coefficient (ICC) between the evaluations of the two examiners, and intra-observer reliability was assessed by the ICC between the two evaluations of one examiner. Results: Fifty-five patients were included in the study (mean age 58.7 years). The ICC for inter-observer reliability of the Brazilian Portuguese version of the mJOA was 0.967, and the ICC for intra-observer reliability was 0.869, both classified as "almost perfect" (> 0.81). Conclusion: The Brazilian Portuguese translated and cross-culturally adapted version of the mJOA questionnaire appears to be valid and reliable. Level of evidence I, Diagnostic Studies, Investigating a Diagnostic Test.


RESUMO Objetivo: Avaliar a confiabilidade intra e interobservador da versão do questionário mJOA traduzida e adaptada culturalmente para o português brasileiro. Métodos: A confiabilidade da versão em português da escala mJOA foi avaliada em uma amostra de pacientes com mielopatia cervical por dois examinadores com experiência em cirurgia da coluna vertebral. A confiabilidade interobservador foi definida pelo Coeficiente de Correlação Intraclasse (CCI) entre as avaliações dos dois examinadores e a confiabilidade intraobservador pelo CCI entre duas avaliações de um examinador. Resultados: Cinquenta e cinco pacientes foram incluídos no estudo (média de idade: 58,7 anos). O CCI para confiabilidade interobservador da versão brasileira do mJOA foi 0,967 e o CCI para a confiabilidade intraobservador foi 0,869, ambas classificadas como "quase perfeita" (> 0,81). Conclusão: A versão do questionário mJOA traduzida e adaptada culturalmente para o português brasileiro demonstrou-se válida e confiável. Nível de Evidência I, Estudos diagnósticos, Investigação de um Exame para Diagnóstico.

5.
Coluna/Columna ; 10(4): 284-285, 2011. tab
Article in Portuguese | LILACS | ID: lil-610636

ABSTRACT

OBJETIVO: Avaliar a prevalência da escoliose degenerativa do adulto (tipo de novo) em uma amostra da população brasileira. MÉTODOS: foram estudados 1149 exames radiográficos simples de abdome na incidência anteroposterior, realizados no Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, no período de julho de 2008 a fevereiro de 2009. RESULTADOS: a prevalência da escoliose do adulto na amostra da população estudada foi de 1,74 por cento, sendo maior na faixa etária entre 60 e 69 anos. Não foi observada diferença estatisticamente significativa (p = 0,41) entre os sexos, e a medida média do ângulo da escoliose foi de 19,1º. CONCLUSÃO: A PREVAlência da escoliose do adulto na amostra da população estudada está dentro dos resultados já apresentados na literatura.


OBJECTIVE: to evaluate the prevalence of adult degenerative scoliosis (de novo) in a sample of the population. METHODS: We studied 1149 plain anteroposterior abdominal radiographs in achieved in the Hospital das Clínicas of the Faculty of Medicine of Ribeirão Preto from July 2008 to February 2009. RESULTS: The prevalence of scoliosis in the adult population sample studied was 1.74 percent, being higher in the group aged between 60 and 69 years. There was no statistic significant difference (p=0.41) between the sexes, and the average length of the angle of scoliosis was 19.1º. CONCLUSION: The prevalence of scoliosis in the sample of the adult population studied is consistent with the presented results in the literature.


OBJETIVO: Evaluar la prevalenciade la escoliosis degenerativa del adulto (tipo de 'novo') en una muestra de la población. MÉTODOS: Se estudiaron 1149 radiografías de abdomen simple en proyección anteroposterior; esto se realizó en el Hospital de la Facultad de Medicina de Ribeirão Preto de julio de 2008 a febrero de 2009. RESULTADOS: La preponderanciade la escoliosis en la población de la muestra de adultos estudiados fue de 1,74 por ciento, siendo mayor en el grupo entre 60 y 69 años. No hubo diferencias significativas (p = 0,41) entre los sexos, y la medida promediodel ángulo de la escoliosis fue de 19,1º. CONCLUSIÓN: La prevalencia de la escoliosis en la muestra de adultos de la población estudiada está de acuerdo con los resultados presentados en la literatura.


Subject(s)
Low Back Pain , Scoliosis , Spine
6.
Coluna/Columna ; 9(4): 455-461, out.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-572353

ABSTRACT

OBJETIVO: descrever a caracterização histológica e radiográfica do método de indução da degeneração do disco intervertebral da cauda de ratos Wistar induzida por meio de punção. MÉTODOS: ratos Wistar machos adultos foram anestesiados, radiografados e submetidos à punção dos discos intervertebrais localizados entre a sexta e a sétima e a oitava e nona vértebras coccígeas. Para a punção foi utilizada agulha de 20G, que foi introduzida até o ânulo fibroso, e foi realizada dupla rotação de 360º, mantendo-se a mesma posição durante 30 segundos antes da retirada. O disco intermediário aos segmentos lesados (7-8) não foi puncionado e foi utilizado como controle. Foi selecionado o período pós-lesão de 30 dias (n=9) para sacrifício e análise dos discos intervertebrais. Os animais foram radiografados 30 dias após a lesão para análise da altura do disco intervertebral. Os segmentos da cauda foram removidos, fixados e desmineralizados, processados e corados com Hematoxilina-Eosina para avaliação histológica. RESULTADOS: a análise radiográfica revelou a redução significativa da altura dos discos lesados em relação ao controle. A avaliação histológica revelou alterações no núcleo pulposo e ânulo fibroso dos discos lesados em relação ao controle. Não foram observadas diferenças na intensidade de lesão entre os discos proximal e distal. CONCLUSÃO: a degeneração do disco intervertebral da cauda de ratos Wistar induzida por meio de punção mostrou ser método reprodutível para estudo da degeneração do disco intervertebral. Esse modelo mostrou validade para avaliação experimental de novas intervenções terapêuticas nos processos de degeneração do disco intervertebral.


OBJECTIVE: to report the induction of intervertebral disc degeneration of the rat caudal spine by needle puncture and its radiographic and histologic characterization. METHODS: adult male Wistar rats were anesthetized, submitted to the X-Ray and then to the needle puncture (20G) of intervertebral disc between the sixth and seventh (proximal segment) and the eighth and ninth (distal segment) coccygeal vertebrae. Radiographies were taken 30 days after lesion for analysis of intervertebral disc height. The intermediate disc (7-8) to injured segments was not punctured and was considered as control. All segments were removed, fixed and demineralized, processed and stained with Hematoxylin-Eosin for histological evaluation. RESULTS: radiographic analysis revealed significant reduction in disc height of lesioned discs compared to control. Similarly, histological analysis revealed significant changes in the nucleus pulposus and annulus fibrosus of the lesioned discs (proximal and distal) relative to the control. There was no difference in the intensity of injury between the proximal and distal discs. CONCLUSION: the experimental model of tail intervertebral disc degeneration by needle puncture reproduced the steps of the intervertebral disc degeneration, assessed by different instruments, and it can be used for experimental evaluation of new therapeutic interventions for intervertebral disc degeneration process.


OBJETIVO: describir la caracterización histológica y radiográfica del método de inducción de la degeneración del disco intervertebral de la cola de ratas Wistar, inducida por medio de la punción. MÉTODOS: ratas Wistar machos adultos fueron anestesiados, radiografiados y sometidos a la punción de los discos intervertebrales localizados, entre la sexta y la séptima; y la octava y novena vértebras coccígeas. Para la punción, fue utilizada una aguja de 20G, que fue introducida hasta el ánulo fibroso, y fue realizada una dupla rotación de 360º, manteniendo esta posición durante 30 segundos, previamente a la retirada. El disco intermediario a los segmentos lesionados (7-8) no fue puncionado y fue considerado como control. Fue seleccionado el periodo post-lesión de 30 días (n=9) para sacrificio y análisis de los discos intervertebrales. Los animales fueron radiografiados 30 días después de la lesión para análisis de la altura del disco intervertebral. Los segmentos de la cola fueron removidos, fijados y desmineralizados, procesados y coloreados con hematoxilina-eosina para evaluación histológica. RESULTADOS: el análisis radiográfico mostró una reducción significativa de la altura de los discos lesionados en relación al control. La evaluación histológica mostró alteraciones en el núcleo pulposo y el ánulo fibroso de los discos lesionados en relación al control. No fueron observadas diferencias en la intensidad de la lesión entre los discos proximal y distal. CONCLUSIÓNES: la degeneración del disco intervertebral de la cola de ratas Wistar inducida por medio de punción mostró ser un método reproducible para el estudio de la degeneración del disco intervertebral. Ese modelo mostró validez para la evaluación experimental de nuevas intervenciones terapéuticas en los procesos de la degeneración del disco intervertebral.


Subject(s)
Humans , Histology , Intervertebral Disc , Rats, Wistar
7.
Coluna/Columna ; 9(3): 322-327, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-570588

ABSTRACT

OBJETIVOS: avaliar, por meio da tomografia computadorizada, os parâmetros morfométricos do processo odontoide relacionados com a sua fixação interna. MÉTODOS: cinquenta e cinco exames de tomografia computadorizada (TC) da coluna cervical que permitissem o estudo do áxis foram utilizados para o estudo. Destes, 24 (47 por cento) pertenciam a pacientes do sexo masculino e 31 do sexo feminino. A média de idade foi de 42,05 anos (± 15,82). Foram excluídos os casos com diagnóstico de tumores, infecções, sequelas de fratura, artrose muito avançada ou malformações congênitas. Nenhum dos exames tinha como indicação problemas relacionados à coluna cervical alta. Foram avaliados os seguintes parâmetros: 1 - comprimento estimado do implante (CEI), 2 - angulação do parafuso (aP), 3 - diâmetro transverso mínimo (DTmín) e 4 - diâmetro anteroposterior mínimo (DAPmín). Foi utilizado o teste t de Student para comparar os resultados entre o grupo de pacientes do sexo masculino e do feminino. RESULTADOS: o valor médio do CEI foi de 37,95 mm ± 3,44 para a população geral do estudo. O valor médio da angulação do parafuso (aP) foi de 60,91º ± 4,06. O diâmetro transverso mínimo (DTmín) foi de 9,05 mm ± 0,88 e o diâmetro antero-posterior mínimo DAPmín foi de 10,35 mm ±1,04. Os valores do CEI e do DAPmín na população masculina foram significativamente maiores do que aqueles encontrados na feminina, enquanto os outros parâmetros não apresentaram diferenças entre os dois sexos na população estudada. Dos 55 pacientes, 39 por cento apresentaram DTmín < 9 mm, valor mínimo considerado para a colocação de dois parafusos de 3,5 mm. CONCLUSÕES: em nossa população, o sexo masculino apresentou valores significativamente maiores de CEI e DAPmín do que os encontrados no sexo feminino.


OBJECTIVES: to evaluate through computerized tomography the morphometric parameters of the odontoid process related to its internal fixation. METHODS: computed tomographic (CT) scans of 55 patients were analyzed. There were 24 men (47 percent) and 31 women. Mean age was 42.05 years (± 15.82). Patients with tumors, infections, fractures, congenital malformations, and advanced arthritis were excluded. The following measurements were recorded: 1 - estimated implant length (SIL), screw angle (SA), minimal antero-posterior diameter (Min APD), and minimal transverse diameter (Min TD). Statistical analysis was performed using Studentïs t test to compare the results among male and female patients. RESULTS: the main value of the SIL was measured as 39.95 mm ± 3.44 to the total population of this study. The main value of the SA was 60.91º ± 4.06. The Min APD was 9.05 mm ± 0.88, and the Min TD was 10.35 mm ± 1.04. The mean dimensions of SIL and Min TD in the population was significantly larger in men than in women, while others parameters presented no difference among both sex in the studied population. Of the 55 patients 39 percent presented Min TD < 9mm, the critical diameter for the placement of two 3.5 mm cortical screws with tapping. CONCLUSIONS: in our population, men presented significantly bigger values of SIL and Min APD than that found in women.


OBJETIVOS: evaluar, por medio de la tomografía computarizada, los parámetros morfométricos del proceso odontoides relacionados con su fijación interna. MÉTODOS: para el estudio, fueron utilizados 55 exámenes de tomografía computarizada (TC) de la columna cervical que permitieran el estudio del axis. De éstos, 24 (47 por ciento) pertenecían a pacientes del sexo masculino. El promedio de edad fue de 42.05 años (± 15,82). Fueron excluidos los casos con diagnóstico de tumores, infecciones, secuelas de fracturas, artrosis muy avanzada o malformaciones congénitas. Ninguno de los exámenes tenía como indicación problemas relacionados a la columna cervical alta. Fueron evaluados los siguientes parámetros: 1- longitud estimada del implante (CEI); 2 - angulación del tornillo (αP); 3 - diámetro transverso mínimo (DTmín) y 4 - diámetro anteroposterior mínimo (DAPmín). Fue utilizado el test t de Student para comparar los resultados entre el grupo de pacientes del sexo masculino y el femenino. RESULTADOS: el valor promedio de la CEI fue de 37,95 mm ± 3,44 para la población general del estudio. El valor promedio de angulación del tornillo (αP) fue de 60,91º ± 4,06. El diámetro transverso mínimo (DTmín) fue de 9,05 mm ± 0,88 y el diámetro anteroposterior mínimo (DAPmín) fue de 10,35 mm ± 1,04. Los valores de la CEI y del DAPmín en la población masculina fueron significativamente mayores de aquellos encontrados en la femenina, mientras que los otros parámetros no presentaron diferencias entre los dos sexos en la población estudiada. De los 55 pacientes, 39 por ciento presentaron DTmín menor que 9 mm, un valor mínimo considerado para la colocación de dos tornillos de 3,5 mm. CONCLUSIONES: en nuestra población, el sexo masculino presentó valores significativamente mayores de la CEI y del DAPmín cuando comparados con los encontrados en el sexo femenino.


Subject(s)
Humans , Axis, Cervical Vertebra , Fracture Fixation, Internal , Odontoid Process , Orthopedic Fixation Devices , Spine , Tomography, Spiral Computed
8.
Rev. bras. ortop ; 43(10): 452-459, out. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-512061

ABSTRACT

OBJETIVO: Avaliar o torque de inserção e a força de arrancamento de três diferentes parafusos utilizados para a fixação anterior da coluna vertebral, considerando a influência do diâmetro do orifício-piloto (DOP), a densidade dos corpos de prova (CDP) e o desenho da rosca dos parafusos. MÉTODOS: Foram utilizados CDP de poliuretana com duas densidades: 0,16 e 0,32g/cm³, e três tipos de parafusos (USS I, USS II posterior e USS II anterior). Na primeira etapa o orifício-piloto foi feito com sonda de 3,8mm para todos os parafusos; na segunda etapa, com sonda menor do que o diâmetro interno dos parafusos (3,5mm para os parafusos USS I; 3,4mm para os parafusos USS II posterior e 3,0mm para os parafusos USS II anterior). Foram formados 12 grupos experimentais com dez corpos de prova em cada grupo, de acordo com a densidade da poliuretana, DOP e tipo de parafuso utilizado. O torque foi mensurado durante a inserção dos parafusos e a força de arrancamento por meio de ensaio mecânico em máquina universal de teste. RESULTADOS: O torque máximo de inserção apresentou valores decrescentes nos corpos de prova de 0,16g/cm³ e 0,32g/cm³ e em todos os diâmetros do orifício-piloto. A força máxima de arrancamento, nos corpos de prova de 0,16g/cm³ e diâmetro da perfuração de 3,8mm, foi maior nos parafusos USS II posterior que nos parafusos USS I. Com o diâmetro da perfuração menor do que o diâmetro interno do parafuso, os parafusos USS II posterior e anterior apresentaram valores maiores que o parafuso USS I. Nos corpos de prova com 0,32g/cm³ de densidade e diâmetro de perfuração de 3,8mm, a força de arrancamento do parafuso USS II posterior e a do USS I foram maiores que a do parafuso USS II anterior. Com o diâmetro da perfuração menor que o diâmetro interno, os valores foram decrescentes entre o USS II posterior, USS II anterior e USS I. CONCLUSÕES: O torque de inserção e a força de arrancamento dos parafusos utilizados para fixação anterior da coluna vertebral ...


OBJECTIVE: To evaluate insertion torque and pullout strength of three different screws used in the anterior fixation of the spine, considering the influence of the diameter of the pilot hole (DOP), the test specimen density (CDP), and the screw thread design. METHODS: The authors used polyurethane test specimens with two densities: 0.16 and 0.32 g/cm³, and three types of screws (USS I, USS II posterior, and USS II anterior). In the first stage, the pilot hole was made with a 3.8 mm probe for all screws; in the second stage, with a probe smaller than the inner diameter of the screws (3.5 mm for screws USS I; 3.4 mm for USS II posterior screws, and 3.0 mm for USS II anterior screws). 12 experimental groups were formed with ten specimen tests in each group, according to the polyurethane density, DOP, and the type of screw used. Torque was measured during insertion of the screws and the pullout strength by a mechanical assay in a universal test machine. RESULTS: The maximum insertion torque presented a decreasing value in test specimens of 0.16 g/cm³ and 0.32 g/cm³ and in all pilot hole diameters. Maximum pullout strength in test specimens of 0.16 g/cm³ and 3.8 mm of perforation diameter was greater in USS II posterior screws than in USS I screws. With the perforation diameter smaller than the inner screw diameter, USS II posterior and anterior screws presented higher values than the USS I screw. In test specimens with 0.32 g/cm³ of density and perforation diameter of 3.8 mm, the pullout strength of USS II posterior and USS I screws was greater than that of USS II anterior screws. With the smaller perforation diameter than the inner diameter, the values were decreasing between the USS II posterior screw, then the USS II anterior screw, and then the USS I screw. CONCLUSION: Insertion torque and pullout strength of the screws used in the anterior fixation of the vertebral spine are influenced by the test specimen density, by the screw thread ...


Subject(s)
Biomechanical Phenomena , Bone Screws , Orthopedic Fixation Devices , Spine
9.
Rev. bras. ortop ; 43(8): 351-356, ago. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-494105

ABSTRACT

OBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante.


OBJECTIVE: To study acute changes in the interface between screws and vertebral bone tissue, considering the pilot hole diameter in relation to the inner diameter of the screw. METHODS: The study was carried out in sheep, and the second cervical vertebra was selected for the study. Cortical screws were used, with 3.5 mm of external diameter (2.4 mm of inner diameter) and 14 mm in length. Four experimental groups were formed: 1 2.0 mm pilot hole and placement of 3.5 mm screw; 2 - 2.5 mm pilot whole and placement of 2.5 mm screw; 3 - 2 mm pilot hole with no screw placement; and 4 2.5 mm pilot whole with no screw placement. RESULTS: Group 1 (pilot hole smaller than the inner diameter of the screw) presented more bone density inside the implant thread and more bone density in the mirror area than group 2 (pilot hole larger than the inner diameter of the screw). The contact surface between bone tissue and the implant was larger in group 2 when compared to group 1. The comparison of bone density in the mirror area among the groups with and without screw placement (1 and 3) and (2 and 4) showed that bone density was greater in the groups with screw placement. No statistical differences were seen among the comparisons of the experimental groups. CONCLUSION: The use of a pilot hole with a smaller diameter than the inner diameter of the screw tended to cause more bone compaction around the screw.


Subject(s)
Animals , Bone Screws , Internal Fixators , Orthopedic Fixation Devices , Spine , Sheep
10.
Rev. bras. ortop ; 43(7): 293-299, jul. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-492432

ABSTRACT

OBJETIVO: Observar a influência do diâmetro do orifício-piloto nos diferentes modos de preparo: sonda de ponta romba, sonda de ponta cortante e broca, com o propósito de avaliar o nível de resistência ao arrancamento de parafusos com diâmetro diverso. MÉTODOS: Parafusos de 5, 6 e 7mm foram inseridos nos corpos de prova de osso bovino. O orifício-piloto foi confeccionado por meio de sonda de ponta romba, sonda de ponta cortante e broca. O diâmetro da perfuração foi menor, igual e maior do que o diâmetro interno do parafuso. Após a inserção dos implantes, nos três diferentes diâmetros para cada modo de preparo do orifício-piloto, foram realizados os ensaios mecânicos de arrancamento. Os ensaios mecânicos realizados em máquina universal de ensaio Emic®, software Tesc 3.13, célula de carga de 2.000N, velocidade de aplicação de força de 2mm/min, pré-carga de 5N e tempo de acomodação de 10 segundos. A propriedade avaliada nos ensaios mecânicos foi a força máxima de arrancamento. RESULTADOS: No grupo de parafusos de 5 e 6mm foi observado aumento na resistência ao arrancamento quando o diâmetro do orifício-piloto era menor que o diâmetro interno do parafuso em todos os modos de preparo (sonda de ponta romba, sonda de ponta cortante e broca). Não foi observada diferença estatística no grupo de parafusos de 7mm para todos os diâmetros de perfuração e modo de preparo do orifício-piloto. CONCLUSÃO: O diâmetro do orifício-piloto influencia a resistência ao arrancamento dos parafusos de sistema de fixação vertebral. A realização de orifício-piloto de diâmetro maior que o diâmetro interno do parafuso reduz a resistência ao arrancamento do implante, independente do modo de preparo do orifício-piloto.


OBJECTIVE: To observe the relevance of the pilot hole in the different manners of preparation: dull-tipped probe, cutting-tip probe, and burr, for the purpose of evaluating the level of pullout strength of screws with different diameters. METHODS: Screws of 5, 6, and 7 mm were inserted in the bovine bone test samples. The pilot hole was made with the dull-tipped probe, the cutting-tip probe, and burr. The perforation diameter was smaller, equal, and larger than the inner diameter of the screw. Mechanical pullout assays were performed in the three diameters for each manner of preparation of the pilot hole after inserting the implant. The mechanical assays were performed in an Emic®, Software Tesc 3.13 universal machine with load cell of 2000 N, load application speed of 2 mm/min, pre-load of 5 N, and accommodation time of 10 seconds. The property evaluated in the mechanical assays was the maximum pullout strength. RESULTS: In the group with 5 mm and 6 mm screws, and increase was observed in the pullout strength when the pilot hole diameter was smaller than the inner diameter of the screw in all manners of preparation (dull-tipped probe, cutting-tip probe, and burr). No statistical difference was seen in the seven millimeter screw group for all perforation diameters and manners of preparing the pilot hole. CONCLUSION: The pilot hole diameter has an influence upon the pullout strength of the screws in the vertebral fixation system. The making of a pilot hole with diameter larger than the inner diameter of the screw reduces the pullout strength of the implant, irrespective of the manner of preparation of the pilot hole.


Subject(s)
Animals , Cattle , Biomechanical Phenomena , Bone Screws , Orthopedic Procedures , Spine
11.
Rev. bras. ortop ; 43(4): 116-125, abr. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-484527

ABSTRACT

OBJETIVO: Apresentar um modelo experimental de hérnia de disco e sua validação para estudo da hiperalgesia mecânica e térmica produzidas pelo contato do núcleo pulposo (NP) com as estruturas nervosas envolvidas nessa afecção. MÉTODOS: Foram utilizados ratos Wistar, sendo o NP autólogo retirado da região sacrococcígea e depositado sobre a dura-máter, raiz nervosa ou gânglios das raízes dorsais L4, L5 ou L6. Os experimentos foram divididos em quatro etapas: 1ª) determinação da estrutura nervosa mais sensível ao contato com o NP; 2ª) identificação do melhor nível lombar para a indução da hiperalgesia; 3ª) determinação da ausência de lesão motora; e 4ª) determinação da influência do procedimento cirúrgico no desenvolvimento do processo inflamatório. A hiperalgesia foi avaliada nos testes de von Frey eletrônico e de Hargreaves e a função motora, pelo teste de rota-rod. RESULTADOS: O NP induziu hiperalgesia de maior intensidade na pata quando em contato com o gânglio da raiz dorsal (GRD) do que em contato com a dura-máter ou a raiz nervosa. Quando em contato com o GRD-L5, o NP induziu hiperalgesia ainda maior que a induzida pelo contato com os GRDs L4 e L6. Não foram observadas lesão motora e influência do processo inflamatório cirúrgico sobre a hiperalgesia. CONCLUSÃO: O GRD é a estrutura mais sensível aos componentes do NP para a produção da hiperalgesia, sendo o quinto nível lombar o que apresentou maior alteração nas sensibilidades mecânica e térmica avaliadas na pata dos animais, de acordo com os métodos utilizados.


OBJECTIVE:The purpose of this study is to present an experimental model of disc herniation and to validate such model to study mechanic and thermal hyperalgesia produced by the contact of the nucleus pulposus (NP) with nerve structures involved in this condition. METHODS: The authors used Wistar rats, the autologous NP being removed from the sacrococcygeal region and deposited on the dura mater, nerve root, or L4, L5, or L6 dorsal root ganglia. The experiments were divided into four steps: 1) determining the nerve structure that is the most sensitive to the contact with NP; 2) identifying the best lumbar level to induce hyperalgesia; 3) determining absence of a motor lesion; and 4) determining the impact of the surgical procedure upon the inflammatory process. Hyperalgesia was evaluated by the von Frey electronic test and the Hargreaves test, and the motor function was evaluated by the rota-rod test. RESULTS: NP induced higher intensity hyperalgesia in the paw when it was in contact with the dorsal root ganglion (GRD) than when it was in contact with the dura mater or the nerve root. Contact with GRD-L5, led NP to induce even higher hyperalgesia than that induced in the contact with L4 and L6 GRDs. No motor lesion and impact of the surgical inflammatory process on hyperalgesia were observed. CONCLUSION: GRD is the structure that is most sensitive to NP components to produce hyperalgesia, the fifth lumbar level being that showed the greatest change in the mechanic and thermal sensitivities evaluated in the paws of the animals, under the methods used.


Subject(s)
Animals , Rats , Hyperalgesia , Intervertebral Disc , Intervertebral Disc Displacement , Low Back Pain , Spine , Rats, Wistar
12.
Rev. colomb. ortop. traumatol ; 22(1)mar. 2008. ilus, graf, tab
Article in Spanish | LILACS | ID: lil-638975

ABSTRACT

Objetivo: observar la influencia del diámetro del orificio piloto en los diferentes modos de preparación (punzón de punta roma, punzón de punta cortante y broca). Materiales y métodos: tornillos de seis, cinco y siete milímetros fueron colocados en los cuerpos de prueba de hueso bovino. El orificio piloto fue realizado por medio de punzón de punta roma, punzón de punta cortante y broca. El diámetro de perforación fue menor, igual y mayor que el diámetro interno del tornillo. Después de colocar los implantes, en los tres diferentes diámetros para cada modo de preparación del orificio piloto, fueron realizados los ensayos mecánicos de arrancamiento. Los ensayos mecánicos fueron realizados en una máquina universal de ensayo Emic®, Software Tesc 3.13, con una célula de carga de 2000 N, una velocidad de aplicación de fuerza de 2 mm/min, una precarga de 5 N y un tiempo de acomodación de 10 segundos. La propiedad evaluada en los ensayos mecánicos fue la fuerza máxima de arrancamiento. Resultados: en el grupo de tornillos de cinco y seis milímetros se observó un aumento en la resistencia al arrancamiento cuando el diámetro del orificio era menor que el diámetro interno del tornillo en todos los modos de preparación (punzón de punta roma, punzón de punta cortante y broca). No se observaron diferencias estadísticas en el grupo de tornillos de siete milímetros con ninguno de los diámetros de perforación y modos de preparación del orificio piloto. Conclusiones: el diámetro del orificio piloto influye en la resistencia al arrancamiento de los tornillos del sistema de fijación vertebral. La realización de un orificio piloto de un diámetro mayor que el diámetro interno del tornillo reduce la resistencia al arrancamiento del implante, independiente del modo de preparación del orificio piloto.


Subject(s)
Bone Screws , Biomechanical Phenomena , Spine/surgery , Orthopedic Fixation Devices , Prostheses and Implants
13.
Acta ortop. bras ; 15(1): 30-34, 2007. graf, tab, ilus
Article in Portuguese | LILACS | ID: lil-450334

ABSTRACT

Foram estudados 20 pacientes portadores de luxação traumática uni ou bifacetária da coluna cervical tratados pela artrodese e fixação anterior. Os pacientes foram avaliados por meio de parâmetros clínicos, radiológicos e funcionais. Os pacientes foram seguidos por um período que variou de 1 a 14 anos. A consolidação radiológica da artrodese foi observada em todos os pacientes e 1 paciente apresentou soltura tardia de um dos parafusos. A angulação no plano sagital do segmento vertebral lesado apresentou alteração no período pré-operatório, sendo obtido redução no pós-operatório imediato e manutenção da mesma após um ano do tratamento cirúrgico. A avaliação clínica e funcional de acordo com o SF-36 e escala de dor e trabalho de Denis demonstrou bons resultados clínicos sendo as principais queixas pós-operatórias decorrentes do grau da lesão neurológica. O hematoma da ferida operatória, que necessitou de drenagem cirúrgica foi a única complicação observada em um paciente. A realização da artrodese e fixação anterior para o tratamento das luxações traumáticas uni ou bifacetárias da coluna cervical apresentou bons resultados clínicos, radiológicos, funcionais e baixo índice de complicações, justificando nossa preferência por esse método de tratamento para esse tipo de lesão da coluna cervical.


Twenty patients presenting with single-or bi-faceted traumatic dislocation of the cervical spine treated by means of arthrodesis and anterior fixation have been studied. Patients were assessed by clinical, X-ray, and functional parameters. The patients were followed up during a period ranging from 1 to 14 years. Union of the arthrodesis, as evidenced by X-ray, was noticed in all patients, with one patient presenting with late loosening of one of the screws. Angulations at sagittal plane of the injured vertebral segment showed a change preoperatively, with reduction being achieved at the early postoperative period and maintenance after one year post-surgically. The clinical and functional assessment according to SF-36 and to DenisÆ pain and effort scale showed good clinical results with the major postoperative complaints being resultant from the neurological injury degree. The hematoma observed on surgical wound, which required surgical drainage was the only complication reported in a patient. The approach employing arthrodesis and anterior fixation for treating single- or bi-faceted traumatic dislocations of the cervical spine showed good clinical, X-ray, and functional outcomes, as well as a small complications rate, thus justifying our preference for this method when treating these kinds of cervical spine injury.


Subject(s)
Humans , Male , Female , Child , Adolescent , Young Adult , Middle Aged , Spinal Fusion/methods , Spinal Injuries/surgery , Spinal Injuries , Spinal Injuries/rehabilitation , Spinal Cord Injuries/rehabilitation , Brazil , Cervical Vertebrae , Evaluation of Results of Therapeutic Interventions , Retrospective Studies
14.
Acta ortop. bras ; 15(2): 76-79, 2007. tab, graf, ilus
Article in Portuguese | LILACS | ID: lil-458698

ABSTRACT

Foram realizados ensaios mecânicos com o objetivo de avaliar a influência do diâmetro do orifício piloto em relação ao diâmetro interno do parafuso na resistência ao arrancamento dos parafusos do sistema de fixação vertebral aplicados no corpo da vértebra. O estudo foi realizado em duas etapas. Na primeira etapa foram utilizados corpos de prova de poliuretana para a colocação de parafusos de 5mm e, 6mm , e na segunda etapa os parafusos foram inseridos na face lateral dos corpos das vértebras lombares de suínos. O orifício piloto foi realizado com brocas de diâmetro menor, igual ou maior que o diâmetro interno do parafuso. Foram realizados ensaios mecânicos de arrancamento em máquina universal de teste para a avaliação da força máxima de arrancamento dos implantes. Foi observado que o diâmetro do orifício piloto em relação ao diâmetro interno do parafuso influencia na resistência ao arrancamento dos implantes.


Mechanical assays were performed in order to assess the influence of pilot hole diameter versus screw's inner diameter on screw pullout resistance in the vertebral fixation systems applied to the vertebral body. The study was conducted in two stages. In the first, polyurethane test bodies were used for placing 5 and 6 mm screws, and, in the second stage, the screws were inserted into the lateral surface of the lumbar vertebral bodies of pigs. The pilot hole was built with drills with smaller, similar or larger diameter than screws' inner diameter. Mechanical pullout assays were performed using a universal test machine for the assessment of maximum pullout screw resistance. The diameter of the pilot hole versus screw's inner diameter was shown to influence screw pullout resistance.


Subject(s)
Animals , Male , Bone Screws , Polyurethanes , Prostheses and Implants , Spine , Biomechanical Phenomena , Lumbar Vertebrae , Swine
15.
Acta ortop. bras ; 13(1): 38-41, 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-400828

ABSTRACT

As alterações radiográficas da coluna cervical de 81 pacientes em tratamento ambulatorial de artrite reumatóide foram estudadas e correlacionadas com dor a cervical e os sinais neurológicos relacionados com a compressão das estruturas nervosas contidas no canal vertebral. A correlação das alterações radiográficas com a classificação em graus e em estágios da doença preconizados pela ARA (American Rheumatism Association) e classificação da capacidade funcional de Steinbroker foi também realizada. A avaliação radiográfica foi realizada por meio de radiografias em AP, perfil e dinâmicas da coluna cervical. As alterações radiográficas (migração superior do processo odontóide, instabilidade atlanto-axial, instabilidade sub-axial ou erosão do processo odontóide) foram observada em 65 (80,2 por cento) dos pacientes. Foi observado correlação estatisticamente significativa entre a capacidade funcional dos pacientes (classificação de Steibroker) e estágios da doença (ARA ) com as alterações radiográficas da coluna cervical dos pacientes. A presença de alterações radiográficas da coluna cervical dos pacientes com artrite reumatóide não apresentou correlação estatisticamente significativa com a dor ou sinais de compressão nervosa.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Arthritis, Rheumatoid/etiology , Spine/physiopathology , Spine , Chi-Square Distribution , Neck Pain
16.
Acta ortop. bras ; 12(3): 167-173, jul.-set. 2004. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-388049

ABSTRACT

Neste estudo foram avaliados a sensibilidade e precisão dos métodos de Nash e Moe e de Raimondi para a medida da rotação da vértebra torácica e lombar.Três cirurgiões de coluna avaliaram, independentemente, as radiografias de uma vértebra torácica (T9) e de uma vértebra lombar (L2) com graus de rotação que variaram de 0º a 60º e estabeleceram valores de acordo com o método de Nash e Moe e o método de Raimondi.Foram estudadas a concordância entre os examinadores para um determinado método, a variação das medidas obtidas na vértebra torácica e lombar a partir de uma mesma rotação real conhecida e a correlação entre um valor real conhecido de rotação vertebral e a sua estimativa pelos métodos utilizados no estudo . Os resultados mostraram boa concordância entre os examinadores para o método de Nash e Moe, tanto para a vértebra torácica (k médio = 0,66), quanto para a lombar (k médio = 0,80). Pelo método de Raimondi não houve diferença significativa entre os examinadores para a vértebra torácica, no entanto, para a vértebra lombar houve baixa reprodutibilidade do método.Para uma mesma rotação na vértebra torácica e lombar os resultados foram não concordantes pelo método de Nash e Moe, e pelo método de Raimondi os valores observados para a vértebra torácica foram significativamente maiores que os da vértebra lombar. A correlação entre os valores reais e as estimados pelo método de Raimondi para a vértebra torácica mostrou que houve diferença significativa produzida em função da rotação até 20º graus, já para a vértebra lombar, os valores obtidos foram muito próximos do real.


Subject(s)
Humans , Evaluation Study , Rotation , Scoliosis , Spine , Spine/physiopathology
17.
RBM rev. bras. med ; 60(4): 206-212, abr. 2003. ilus
Article in Portuguese | LILACS | ID: lil-344744

ABSTRACT

Os pacientes com artrite reumatóide podem apresentar alteraçöes em nível da coluna cervical que, clinicamente, podem manifestar-se por sinais de instabilidade ou compressäo na medula espinhal ou raízes nervosas. Essas alteraçöes da coluna cervical podem ser assintomáticas e a sua pesquisa por meio de exames radiográficos permite o diagnóstico precoce, que possui importante implicaçäo terapêutica. A migraçäo superior do processo adontóide, a instabilidade atlanto-axial e a subluxaçäo subaxial säo as alteraçöes mais frequentes. O tratamento cirúrgico, empregando os recursos da moderna cirurgia da coluna vertebral, tem permitido a obtençäo de melhores resultados, principalmente quando efetuados nas fases mais precoces da instabilidade e compressäo das estruturas nervosas.


Subject(s)
Humans , Arthritis, Rheumatoid , Spinal Diseases/complications , Spinal Diseases/physiopathology , Cervical Vertebrae/surgery , Cervical Vertebrae/physiopathology , Cervical Vertebrae/injuries , Cervical Vertebrae
18.
Rev. bras. ortop ; 37(4): 99-107, abr. 2002.
Article in Portuguese | LILACS | ID: lil-334653

ABSTRACT

As fraturas da coluna cervical alta apresentam características distintas das da coluna cervical baixa e säo estudadas separadamente. Nesta revisäo säo apresentadas as principais características clínicas, diagnósticas e tratamento das fraturas do côndilo occipital, luxaçäo atlanto-occipital, fratura do atlas, lesäo do ligamento transverso, luxaçäo rotatória atlanto-axial, fratura do processo odontóide e espondilolistese traumática do áxis


Subject(s)
Humans , Child, Preschool , Child , Adult , Middle Aged , Axis, Cervical Vertebra/injuries , Cervical Atlas , Occipital Bone , Odontoid Process , Spinal Injuries , Aged, 80 and over , Diagnosis, Differential , Tomography, X-Ray Computed
19.
Medicina (Ribeiräo Preto) ; 35(1): 41-47, jan.-mar. 2002. tab, graf
Article in Portuguese | LILACS | ID: lil-343859

ABSTRACT

Foi realizado estudo epidemiológico dos pacientes atendidos nos hospitais da cidade de Ribeiräo Preto-SP com fraturas da coluna cervical, devidas ao mergulho em águas rasas, no período de janeiro de 1989 a dezembro de 1999. Nesse período, foram registradas 97 fraturas da coluna cervical por mergulho em águas rasas, sendo que 60 apresentavam lesäo neurológica. O acidente ocorreu durante mergulho em piscinas, em 25 pacientes, e em rios, córregos ou lagoas, em 72. Oitenta e oito (90,72 por cento) pacientes eram do sexo masculino e 9 (9,28 por cento) do feminino, e a faixa etária de maior ocorrência da lesäo foi entre os 10 e 20 anos. Doze pacientes, vítimas de fratura da coluna cervical devido ao mergulho em água rasa, foram entrevistados e constatou-se desinformaçäo e desconhecimento dos riscos e morbidade desse tipo de trauma. Os resultados do estudo epidemiológico e as características dessa modalidade de lesäo indicam que sua prevençäo deva ser estimulada por meio de campanhas educativas


Subject(s)
Child , Adolescent , Adult , Diving , Spinal Fractures , Spinal Injuries , Accidents
20.
Acta ortop. bras ; 9(1): 21-8, jan.-mar. 2001. tab, graf
Article in Portuguese | LILACS | ID: lil-297244

ABSTRACT

Foram estudadas 48 pacientes com câncer da mama e que apresentavam metástases ósseas, com o objetivo de avaliar-se a correlação entre o estadiamento clínico do tumor primário, de acordo com o protocolo do Comitê Americano de Estadiamento do Câncer, e as manifestações esqueléticas das metástases ósseas, tendo sido utilizados como parâmetros para essa avaliação o período de seguimento, o número de metástases, o tipo de lesão, a sua localização e a região do osso acometida. Foi observado correlação entre o estadiamento da lesão primária e o tempo de seguimento, que diminuia à medida que o grau de estadiamento aumentava, não tendo sido observado correlação entre o estadiamento clínico do câncer de mama e os demais parâmetros estudados.


Subject(s)
Humans , Female , Adult , Middle Aged , Breast Neoplasms/etiology , Neoplasm Metastasis , Bone Neoplasms/complications , Neoplasm Staging
SELECTION OF CITATIONS
SEARCH DETAIL